Spot Vital Signs Device 420TB
BP and Temperature
Welch Allyn Spot Vital Signs has made its mark in ambulatory and acute care
settings for its accuracy, durability and cost-effectiveness. Now with updated
features, the fully automated, multiparameter Spot Vital Signs has become the
device of choice for frontline caregivers world-wide.
Hospital-grade equipment now offers enhanced clinical performance and
quality:
- Fast and accurate - completes BP, pulse rate and temperature
- Multiparameter and modular so you can select precisely the vital signs you
need
- Optional Masimo or Nellcor pulse oximetry
- Optional SureTemp thermometry
- IR connectivity to interface with computerised patient records
- Portable - carry it, wheel it, or mount it
- Big, bright, easy-to-read LCD screen
- Offers you one of the lowest priced multiparameter instruments on the
market
- Fully upgradeable to meet your changing needs
- Intergrated long-life battery enhances portability and continuous
operation
- Intuitive design and training materials provide concise, easy training for
your staff
Specifications
Noninvasive Blood Pressure (NIBP)
- Cuff Pressure Range - 0 to 300 mmHg
- Initial Cuff Inflation - 160 mmHg (adjustable)
- Systolic Range - 60 to 250 mmHg
- Diastolic Range - 30 to 160 mmHg
- Mean Arterial Pressure Range - 40 to 190 mmHg
- Blood Pressure Accuracy - Blood pressure meets or exceeds SP10:1992 AAMI
standards
- Blood Pressure Determination Time - 20-45 seconds typical
- Overpressure Cutoff - 315 mmHg +/- 15 mmHg
- Pulse Rate Range (using BP determination) - 40 to 200 bpm
- Pulse Rate Accuracy (using BP determination) +/- 5%
Temperature
- Measurement Range - 30 to 43 degree celcius
- Calibration Accuracy +/- 0.1 degree celcius (monitor mode)
- Determination Time - Oral - Approximately 4 seconds / Axillary -
Approximately 10 seconds / Rectal - Approximately 15 seconds
- Probe - Oral/Axillary - Blue cap / Rectal - Red cap
Mechanical
- Dimensions - Height: 24.6 cm / Length: 14.5 cm / Depth: 12 cm
- Weight - 2.1kg
Electrical
- AC Power Supply - 7.2 V DC at 1.0 A, Rechargeable sealed lead acid
internal battery
- Battery Recharge Time - 90% to 100% after 12 hours. Simultaneously
operates device and charges battery when AC power adapter is plugged in
- Operating Time - A fully charged battery supports 150 typical blood
pressure determinations at 7-minute intervals
Environmental
- Operating Temperature - 10 to 40 degree ceclius
- Operating Relative Humidity - 15% to 90% (noncondensing)
- Operating Altitude - minus 170 m to +4,877 m
- Storage Temperature - minus 20 to 50 degree celius
- Storage Humdity- 15% to 90% (noncondensing)
- EMC Standard - IEC/EN 60601-1-2
Two year warranty on parts and labour